Samancor Ferrometals, Witbank: Venturi Dust Scrubber

The Plant is designed to remove air laden with dust from a number of open processing points on the clients Pelletising Plant. The dust and air is ducted into a Wet Venturi Scrubber Plant where the dust is recovered from the air into the scrub liquor.

The Plant consists of a manually adjustable single stage High Pressure Venturi followed by a Separator Vessel complete with Demister Pad for entraining water droplets and reducing carry-over.

A single stage induced draught, backward curved exhaust fan, draws the exhaust draught / contaminated air through the Scrubber Plant and discharges the clean gas / air to atmosphere via an exhaust stack.The design gas flow rate for the Plant is in excess of 80 000 m3/hr. A circulation pump circulates the scrub liquor via the venturi throat to maximise contact with the dust laden air and the dust slurry discharges into a circulation tank. A slurry transfer pump is used to remove the sludge from the Circulation Tank on a semi continuous basis.

The Plant operates continuously on a 24 hour basis and requires minimal attendance or maintenance.